Phone: +86 158 6967 3111 WhatsApp: +86 157 2687 0335 EN 中文预览
WhatsApp
9m Hydraulic Diesel Mobile Lighting Tower

D955 9m Hydraulic Diesel Mobile Lighting Tower

9 m hydraulic mast · 4 × 400 W LED · Orders from one unit

A project-configurable 9 m hydraulic diesel mobile lighting tower with four 400 W LED floodlights, a choice of Kubota Z482 or D1105 diesel engine. Fuel capacity, engine, voltage, mast, chassis and environmental protection can be configured around your actual operating conditions, project objectives and destination-market requirements.

Start with your quantity, destination and lighting hours. We will help confirm the remaining configuration details.

LUMTA D955 hydraulic diesel mobile light tower
9 m / 29.5 ftHydraulic mast
4 × 400 WLED floodlights
KubotaZ482 or D1105 engine options
1,600 WTotal LED lamp rating
Application-led engineering

Configure the machine around the project

General-purpose specifications work for many sites, but mines, road projects and rental fleets often have different requirements for operating intervals, lighting coverage, electrical standards, stability and environmental protection. D955 can be configured to address those conditions without forcing every customer into one fixed specification.

Fuel capacity for your shift

Include the lighting hours per shift and refuelling access in your enquiry. Fuel tank capacity and runtime are confirmed for the quoted package.

Lighting configuration

Select lamp output and beam distribution according to the working area and required ground illuminance.

50 Hz or 60 Hz

Engine speed, generator output, voltage and frequency are matched to the destination country.

Stability-focused structure

Enhanced chassis, wider stabilizers and reinforced components are available for demanding sites.

Environmental protection

Cooling, filtration, anti-corrosion and surface protection can be upgraded for harsh conditions.

Requirements-Based Customization

Configure fuel capacity, mast, tow hitch, chassis, color, logo and control system according to actual operating conditions and project requirements.

D955 9m hydraulic diesel mobile lighting tower deployed
Standard configuration

Heavy-duty mobile lighting foundation

The standard D955 combines a hydraulic mast, high-efficiency LED lighting and a water-cooled diesel engine on a towable stabilized platform.

  • 9 m hydraulic lifting mast
  • Four 400 W LED floodlights
  • 360° mast rotation and 0–90° lamp adjustment
  • IP65-rated LED floodlights
  • Kubota Z482 or D1105 diesel engine options
  • Electric start and five-point stabilization
  • Towable trailer with off-road tyres

Optional 4G/App Remote Control for D955

Configure the D955 with an optional 4G/App module for remote lamp switching, viewing of equipment operating status and remote engine start and stop. Specify the selected Kubota Z482 or D1105 package and the functions required by your site team.

This is a non-standard custom option, quoted separately from the base configuration. Provide the destination and mobile coverage, then confirm the operating-status fields, access arrangements and any SIM/data or platform charges. See our remote-management configuration checklist.

Request D955 with Remote ControlSend D955 Remote-Control Requirements

Product specifications

Technical information

Values below describe the standard platform and documented configuration choices. Final specifications are confirmed for each order.

ItemStandard / ReferenceConfiguration Notes
Mast9 m hydraulic360° rotation; lamp angle adjustable from 0–90°
Floodlights4 × 400 W LEDBeam distribution selected for the target area and illuminance
Total LED power1,600 WFour 400 W LED floodlights
Luminous efficacy195 lm/WSpecified LED lighting efficacy
Total luminous flux312,000 lm4 × 400 W × 195 lm/W; coverage depends on optics, mast height and target illuminance
Lighting coverageProject-specificRequest photometric data for the selected 4 × 400 W lamps and target illuminance
Ingress protectionIP65 floodlightsEnvironmental package can be upgraded by application
Engine optionsKubota Z482 or D1105Confirm the engine version and matched generator in the quotation
Z482 reference engine, 50 Hz packageZ482-BG15001500 rpm; 3.4 kW engine mechanical power, not generator electrical output
Z482 reference engine, 60 Hz packageZ482-BG18001800 rpm; 4.1 kW engine mechanical power, not generator electrical output
Fuel capacityConfirm in quotationSpecify shift length and refuelling access
StabilizationFive-point systemWider stabilizers and reinforced structure available
MobilityTowable trailerOff-road tyres; tow hitch configured for market requirements

Specifications and available options may change with the final project configuration. Confirm operating limits and transport requirements with LUMTA before ordering.

Selection process

From jobsite conditions to the right configuration

01 / APPLICATION

Define the work area

Lighting area, illuminance target, operating hours and site access.

02 / ENVIRONMENT

Review site conditions

Temperature, dust, wind, humidity, corrosion and terrain.

03 / ELECTRICAL

Confirm local standards

Destination country, voltage, frequency and auxiliary requirements.

04 / CONFIGURE

Finalize the platform

Engine, fuel capacity, mast, lights, chassis and protection package.

Applications

Where buyers use the D955 mobile lighting tower

Road maintenance

Mobile illumination for temporary night work zones.

Infrastructure

Dependable temporary lighting for large work areas.

Emergency response

Rapidly deployable illumination for temporary operations.

Coastal projects

Optional corrosion protection for humid environments.

Remote sites

Fuel and structural choices matched to limited access.

Mast-system decision

When does the D955 hydraulic mast fit the project?

Choose the lifting system by setup frequency, operator effort, mast height and the maintenance capability available at the site. The comparison below routes buyers to the current product pages; final configuration remains subject to quotation.

Current modelMast systemConsider whenConfirm before ordering
D9559 m hydraulicThe tower is deployed frequently or the project prefers powered mast lifting and the listed 9 m platform.Hydraulic inspection and maintenance, site conditions, engine and electrical package.
D9517.5 m manual winchA simpler lifting system is preferred and the operator can accept manual setup effort.Setup procedure, winch and cable inspection, required mast height and lighting coverage.
D9537.5 m electricPowered lifting is preferred on a 7.5 m platform without selecting the D955 hydraulic system.Electrical controls, backup lowering procedure, voltage and intended operating conditions.

Do not select a mast system from lifting method alone. Include transport limits, wind and ground conditions, lighting coverage, duty cycle and local service capability in the project review.

Hydraulic light tower quotation checklist

Configure a D955 around the project

The current D955 starting configuration is a 9 m hydraulic mast with four 400 W LED lamps and a choice of Kubota Z482 or D1105 engine. Use the checklist below to define the quotation without working through a long technical specification form.

DecisionInformation to provide
Quantity and destinationNumber of units, destination country or port and required delivery date.
Application and work areaConstruction, mining, roadwork, rental or another use; include work-area dimensions and target illuminance if known.
Operating scheduleHours per night, shifts per week, refuelling access and the operating interval you need to confirm.
Engine packageChoose Kubota Z482 or D1105. The matched generator, rated electrical output and available auxiliary power are stated in the quotation.
Electrical standardRequired voltage, phase, 50 Hz or 60 Hz, sockets and any external equipment load.
Site environmentTemperature, altitude, dust, wind exposure, salt spray, rainfall, ground conditions and noise restrictions.
Transport and trailerMovement within the site or towing on public roads, hitch and brake requirements, transport limits and unloading arrangements.
Documents and delivery scopeRequired manuals, inspection records, packing information, requested certificates and quotation delivery terms.

Options outside the current confirmed configuration are reviewed during quotation. Availability, dimensions, weights, performance and documentation are confirmed for the exact package rather than assumed from a general option list.

Product FAQ

D955 Hydraulic Mobile Lighting Tower FAQs

Is the D955 supplied in only one fixed configuration?

D955 is available with a Kubota Z482 or D1105 engine. Confirm the matched generator, rated electrical output, voltage, frequency and available auxiliary power for the chosen package. Fuel capacity, final equipment and documentation are specified in the quotation.

How is D955 operating time determined?

Fuel consumption varies with engine configuration, lighting load and external equipment. Fuel use and runtime require validation for the selected configuration. Tank capacity alone does not establish operating hours; include site conditions and maintenance status in the review.

What should be provided for a D955 project quotation?

Start with quantity, destination country, application and lighting hours per night. You do not need a final engine or electrical configuration to make an enquiry. If available, add your delivery deadline and any lighting, towing or documentation requirements.

Can the D955 power tools while the lights are on?

Include each tool’s running and starting load in your enquiry. Available auxiliary power depends on the matched generator, actual lighting load, voltage, outlets and circuit protection. Engine model and engine mechanical power alone do not establish the permitted external load.

What should I specify for a D955 diesel light tower in cold weather?

Provide the minimum starting temperature, operating temperature range and site altitude. Ask LUMTA to confirm the engine starting arrangements, hydraulic fluid and seals, battery and cable specifications for the proposed configuration before ordering.

What trailer and brake details should I include in a D955 enquiry?

State whether the light tower will be moved within a site or towed on public roads, and provide the destination, towing vehicle and hitch requirements. Ask the quotation to identify the axle and suspension, loaded trailer weight, parking brake and service brake arrangement for the selected package.

Start with four details

Request a D955 quote — no final configuration needed

Tell us your quantity, destination country, application and lighting hours per night. We can help review the engine and electrical configuration for your project. Include a delivery deadline if you have one.

Optional technical details for a more specific quotation

If available, share the work-area dimensions, target illuminance, tower positions and any glare-sensitive boundaries. Include site temperature, towing requirements and additional equipment loads.

For shipping, add the destination port and unloading arrangements. Confirm packed dimensions, shipment weight, assembly on arrival and container quantity against the final packing plan.

D955 Product Datasheet

Download the current configuration summary: 9 m hydraulic mast, four 400 W LED lamps, 195 lm/W, 312,000 lm and Kubota Z482 or D1105 engine options.

English PDF · 1 page · Updated 24 September 2026

Download D955 Datasheet — English PDF

Confirm the generating package, electrical output, transport details and final supply scope with your quotation. The datasheet is a configuration summary, not a fuel-consumption or runtime test report.

Request a quote for your D955 configuration → · Browse product documents