LUMTA has received an order for one sample hybrid solar–wind mobile light tower with an electric-assist chassis version. The order excerpt specifies the components below. It does not establish delivered performance, operating hours, site illumination or completed commissioning. This is an order-specific configuration, not a standard specification for every LUMTA light tower.
For a buyer considering a similar system, the useful starting point is the complete load and operating scenario: lighting hours, other connected equipment, available sun and wind, and how the unit will be moved. Send those details with your enquiry so the configuration can be checked rather than copied blindly.
Request a project-specific solar–wind light tower quote — share your site, lighting hours, other electrical loads and quantity. If a specification is unknown, ask LUMTA to recommend a configuration. In the form, select Solar-Wind Hybrid Light Tower (Custom Project) under Product / Model Interest.
Not sure what to specify yet? Build a guided project enquiry. In the power-system step, choose “Solar-wind hybrid (custom project)” or select “Not sure” for a recommendation.
To compare energy routes, review LUMTA’s solar mobile light towers for solar-based models and hybrid mobile light towers for solar–diesel configurations with generator backup. Those pages describe different systems; neither is a specification or performance result for this solar–wind sample order.
What the sample order specifies
| System | Scope recorded in the sample order | What to confirm for another project |
|---|---|---|
| Base assembly | Body assembly with battery cabinet; electric-assist chassis version | Chassis interface, movement method and destination requirements |
| Solar | Three 450 W monocrystalline panels with single-axis automatic tracking and controller | Site exposure, tracking clearance and mounting arrangement |
| Wind | Two 700 W vertical-axis turbines, including brackets | Local wind conditions, siting and mounting suitability |
| Storage | 32 kWh LiFePO4 energy-storage battery with BMS | Usable energy, operating temperature and the proposed load profile |
| Power control | Wind–solar hybrid inverter-controller described as pure sine wave | System voltage, output and equipment compatibility |
| Distribution | Grid charger listed as 40/60/80 A options, six BS1363 sockets and cables | The charger selection, socket standard and destination voltage |
| Lighting | Four detachable 100 W LED floodlights, specified as IP66 | Coverage, mounting, beam pattern and operating schedule |
| Packing | Fumigation-free wooden case in this order | Packing and shipping requirements for the destination |
The 450 W panel, 700 W turbine and 32 kWh battery figures are component ratings or stated capacity, not a forecast of solar or wind production or a verified runtime. Adding component ratings does not determine the energy available at a particular site.
How to request a comparable configuration
- Describe the job. Tell us the country, site type, area to illuminate, operating hours per night and number of units.
- List every electrical load. Include lighting, cameras, communications, charging and any other equipment, with the hours each must operate.
- Describe the energy conditions. Share the available solar exposure, wind conditions, seasonal constraints and any grid-charging access. If these are unknown, say so.
- Confirm mobility and interfaces. Explain how the tower will move, the required chassis connection, socket/voltage standard and any transport restrictions.
- Identify the project scope. State whether you need supply only, remote installation guidance or a separately quoted on-site service, plus your delivery location and target date.
The sample order includes remote video or online guidance for assembly, chassis docking and commissioning. On-site installation was a separate item for that order; service availability and cost for another project must be confirmed in its own quotation.
Send your requirements to LUMTA. If you are unsure of a specification, write “please recommend a configuration” and give us the operating conditions you do know.
Frequently asked questions
Does the 32 kWh battery guarantee a particular runtime?
No. Runtime depends on usable battery energy, the total load over time, system losses, charging input and operating conditions. The order excerpt does not provide a verified runtime.
Are the three solar panels and two wind turbines enough for my site?
Their nameplate ratings alone cannot answer that. A project review needs site conditions, lighting and auxiliary loads, the duty cycle and the required charging margin.
Is this a standard LUMTA model with a fixed price?
No. This page describes one sample order. Configuration, scope, delivery and commercial terms need a project-specific quotation.
Can I ask for a recommendation if I do not know the battery or charger size?
Yes. Share your location, nightly operating hours, lighting area, other electrical loads and any site constraints. LUMTA can discuss a suitable configuration for quotation.