Home / Telescopic Lighting Towers
A telescopic light tower is a mobile lighting unit whose mast extends in nested sections, lifted by manual winch, electric, hydraulic or pneumatic power, to raise LED floodlights to working height and retract again for towing.
Compare telescopic lighting towers by mast lifting method, working height and deployment routine. Review manual-winch, electric, hydraulic and pneumatic model options, then confirm the configuration that fits your lighting task and site.
Request a Mast Configuration & Quote Compare Lifting Methods
Send the quantity, destination, required height, setup frequency and preferred lifting method if known. Confirm lighting load, deployment space, transport and maintenance requirements with the selected model.
Need telescopic light towers?
Tell us the mast height, power source and quantity; we quote FOB/CIF within 24 hours. MOQ 1 unit.
- 4LT1600M9Z482: 9 m electric mast, Kubota diesel, up to 68 h
- LFNVP4000: hydraulic mast, 440,000 lm for mines
- 4LT600M9AH1200: 9 m hand-winch mast, solar, up to 20 h
Compare the mast lifting methods
LUMTA’s diesel catalogue lists the following mast lifting methods. These are catalogue references for model selection; confirm the mechanism, controls and supplied accessories in the quotation for your chosen configuration.
| Catalogue lifting method | Model route | What to confirm before ordering |
|---|---|---|
| Manual winch | 4LT1600M9CC6.5KW (9 m) or 4LT1600M7BATFC (7 m) | Winch arrangement, operator access, working height and the supplied operating instructions |
| Electric | 4LT1600M9Z482 (9 m) | Lifting power supply, controls, operating limits and the procedure for a loss of power |
| Hydraulic | LFNVP4000 (9 m) | Hydraulic configuration, controls, inspection requirements and the matched mast height |
| Pneumatic | Custom build on request (no standard model) | Air supply, mast support or locking arrangement and the specified lowering procedure; configuration and price are confirmed per project |
Ask which components are included and which require a separate option or site provision. For a closer comparison of selection considerations, read the mast lifting method guide.
Telescopic masts in production
Mast sections, the hand winch on a manual mast and the LED head at full height on LUMTA light towers.
Telescopic light tower specifications: diesel and solar models
All LUMTA telescopic light towers below are built at our factories in Shandong and Yueqing, Zhejiang. Compare mast height, lifting method and lighting across the diesel and solar range, then open the model page for the full specification.
| Model | Power | Mast height | Mast lifting | LED lighting | Key data |
|---|---|---|---|---|---|
| 4LT1600M9CC6.5KW | Diesel | 9 m | Manual winch, 360° rotation | 4 × 400 W LED (208,000 lm) | Changchai 380, 6.5 kW generator; 110 L tank |
| 4LT1600M9Z482 | Diesel | 9 m | Electric, 359° rotation | 4 × 400 W LED (208,000 lm) | Kubota Z482; 110 L tank; 860 kg |
| LFNVP4000 | Diesel | 9 m, 8 sections | Hydraulic | 4 × 1000 W metal halide (440,000 lm) or 4 × 400 W LED | Kubota, Yanmar, Changchai or FAW Xichai; 90 L tank |
| 4LT1600M9BAT8KW | Diesel | 9 m | Manual winch | 4 × 400 W LED (160,000 lm) | ANMAX 8 kW generator; 520 kg |
| 4LT1600M7BATFC | Diesel | 7 m | Manual winch | 4 × 400 W LED (160,000 lm) | BAT air-cooled diesel; 550 kg |
| WK1600M5 | Diesel or gasoline | 1.7–4.8 m | Hand crank, walk-behind | 4 × 400 W LED (280,000 lm) | 25 L tank; 116 kg without generator |
| 4LT600M9AH1200 | Solar | 9 m, 6 sections | Manual winch | 4 × 150 W LED (84,000 lm) | 3 × 470 W panels; 6 × 200 Ah; 1,180 kg |
| E4LT600M9AH1200 | Solar + diesel | 9 m, 6 sections | Manual winch | 4 × 150 W LED (84,000 lm) | 3 kW diesel generator; up to 28 h on diesel; 1,380 kg |
Common to all eight models: wind rating 20 m/s (72 km/h, Beaufort 8); 8 units per 40 ft container or 4 units per 20 ft container; production 45–60 days after the deposit is received; minimum order 1 unit.
Need more options? See all diesel light towers for sale and solar light towers for sale. Electrical output, fuel tank and transport dimensions are confirmed in the quotation for the version you order.
Confirm the height against the spec sheet
Each model has a one-page spec sheet that lists its mast height, number of sections and lifting method. Check the sheet for the model you are quoting, and keep the same sheet attached to the quotation and order.
| Spec sheet | Mast configuration | Download |
|---|---|---|
| 4LT1600M9CC6.5KW spec sheet | 9 m, manual winch | PDF, English |
| 4LT1600M9Z482 spec sheet | 9 m, electric | PDF, English |
| LFNVP4000 spec sheet | 9 m, hydraulic, 8 sections | PDF, English |
| 4LT1600M7BATFC spec sheet | 7 m, manual winch | PDF, English |
| 4LT600M9AH1200 spec sheet | 9 m, manual winch (solar) | PDF, English |
These references do not establish one height for every order. Compare the proposed lighting head, mast configuration and transport dimensions together, and keep the same specification revision attached to the quotation and order.
Describe the lighting task and site conditions
Start with the area that needs light, the work being carried out, obstacles and possible tower positions. Send a site sketch or photographs where available. Include the proposed lighting head and any additional mast-mounted equipment so the supplier can assess the complete configuration.
Provide the expected ground conditions, available stabilizer space, exposure to wind and any restrictions on positioning. Ask for the operating limits and deployment instructions that apply to the quoted unit. This category page does not provide a universal wind rating or permission to operate at a particular height.
For the questions to resolve before selecting taller equipment, see the height, wind and stability guide.
Request the matching controls and maintenance documents
A manual-winch specification should not be paired with hydraulic-control instructions as though they describe the same operating procedure. Request an operating manual that matches the actual mast and controls supplied with your tower.
Before comparing proposals, ask for the raising and lowering instructions, inspection requirements, arrangements for securing the mast, and the response to a control or power problem. Confirm the parts and maintenance information available for the quoted configuration, together with responsibility for commissioning and operator training.
Use those documents to plan maintenance. A catalogue description of the lifting method does not establish a common service interval or show that one mechanism will need less maintenance on your site.
Check the transport and deployment envelope
For mast trailers and other mobile towers, compare the equipment’s retracted dimensions, mass, lifting or loading provisions and working footprint against your transport route and site access. Include storage height, gates, available turning space and the surface where the tower will be deployed.
Request the trailer and transport documents relevant to the destination and intended movement. Confirm any towing, registration or road-use requirements locally. A model listing does not establish road approval, a towing speed or suitability for installation on a separate vehicle.
If the tower will move between sites, include the relocation frequency and loading arrangements in the enquiry so they can be considered alongside the mast and lighting package.
Prepare a comparable project quotation
- State the application, destination, quantity and planned delivery requirement.
- Describe the lighting area, preferred working height, lighting head and any additional mounted equipment.
- Identify a preferred lifting method or model, and explain the available power, operator access and site restrictions.
- Provide deployment space, ground and wind conditions, transport constraints and maintenance expectations.
- Request a configuration specification, matched manual, included accessories, optional items and the supply terms needed to compare proposals.
If the energy system is still undecided, compare the diesel light tower catalogue and solar lighting tower catalogue. The mobile light tower range provides the wider equipment routes.
Compare quotations against the same scope of equipment, documents and support. Pricing, delivery, packaging and destination-specific requirements should be confirmed for the selected configuration.
Telescopic lighting tower questions
What is a telescopic lighting tower?
A telescopic lighting tower is a mobile light tower whose mast is made of nested sections that extend to raise the LED lamps above the work area and retract for towing. The mast can be raised by manual winch, electric motor, hydraulics or compressed air.
How high does a telescopic light tower mast go?
LUMTA’s main diesel light towers use 9 m masts; the compact 4LT1600M7BATFC uses 7 m and the walk-behind WK1600M5 4.8 m. The 4LT600M9AH1200 solar and E4LT600M9AH1200 hybrid towers also reach 9 m. Higher masts spread light over a wider area but need more attention to wind, stabilisers and transport height.
Which telescopic mast lifting method is best?
Manual winch masts are simple and low-maintenance; electric and hydraulic masts raise faster with less effort, which helps rental fleets and frequent relocation; pneumatic masts suit applications that need an air-driven mast. See manual vs electric vs hydraulic light tower masts.
Do you make solar telescopic light towers?
Yes. The 4LT600M9AH1200 has a 9 m six-section mast raised by a manual winch, three 470 W solar panels, six 200 Ah gel or LiFePO4 batteries and four 150 W LED lamps (84,000 lm), and runs without fuel. The E4LT600M9AH1200 adds a 3 kW diesel generator for winter and cloudy periods. Compare them on the solar light tower page.
What wind speed can a telescopic light tower withstand?
The 4LT1600M9CC6.5KW, 4LT1600M9Z482, LFNVP4000, 4LT600M9AH1200 and E4LT600M9AH1200 are rated for wind up to 20 m/s (72 km/h, Beaufort 8). Deploy the stabilisers as instructed and lower the mast when wind exceeds the rated limit. Read the height, wind and stability guide for site planning.
What is the minimum order and lead time?
The minimum order is 1 unit. Production takes 45–60 days after the deposit is received. A 40 ft container holds 8 units and a 20 ft container holds 4 units.
How much does a telescopic light tower cost?
There is no single price. It depends on the power system (diesel or solar), mast height and lifting method, lamp output, options, quantity and delivery terms. See the light tower price guide, then send these details for a factory quotation on your exact configuration.
Planning quantity and layout? Read how many light towers you need.
Request a telescopic lighting tower quote
Send your application, destination, quantity and mast requirements. If the model is undecided, describe the site and lighting task so the enquiry can begin with a configuration discussion.




